EVANS COOLING ANALOG REFRACTOMETER
Pre-calibrated for accuracy.
This Evans Cooling Refractometer isĀ designed to accurately test for residual water content. By determining the water content you'll be able to safely set up your cooling system with Evans Cooling products.
- Fast, simple optical method
- Requires only 1 drop of coolant
- Compare optical reading to water content chart
Ā _____________________________________________________________
- Readings are temperature sensitive, so calibrate before each use:
- Calibrate the refractometer by placing a drop of new Evans Waterless on the refractometer glass. Use the small screwdriver supplied with the instrument to turn the calibration screw until the boundary between the upper blue field and the lower white field meet at 57.0.
- Always clean the glass and the daylight plate with a clean, soft cloth after each use and before each reading. Do not place under running water or submerge instrument while cleaning. Store unit in its original case in a cool, dry, area.
- Place a small amount of coolant, obtained from a location in the cooling system where the coolant is well-mixed, on the glass and close the daylight plate.
- Ideal is 3% or 55.7 BRIX; acceptable is 5% or 54.8 BRIX; below 54.4 BRIX, call 888/990-2665 (M-F 9 to 4:30 EST) for technical assistance. Vehicle may be driven with water content 7% or higher - technical intervention is strongly suggested to bring water content into recommended range for optimal performance.Ā
|
Ā ā°Brix
|
% WATER
|
|
57.0
|
0.0
|
|
56.5
|
1.0
|
|
56.1
|
2.0
|
|
55.7
|
3.0
|
|
55.2
|
4.0
|
|
54.8
|
5.0
|
|
54.3
|
6.0
|
|
53.9
|
7.0
|
Product Information
Product Information
Shipping & Returns
Shipping & Returns

EVANS COOLING ANALOG REFRACTOMETER
EVANS COOLING ANALOG REFRACTOMETER
Pre-calibrated for accuracy.
This Evans Cooling Refractometer isĀ designed to accurately test for residual water content. By determining the water content you'll be able to safely set up your cooling system with Evans Cooling products.
- Fast, simple optical method
- Requires only 1 drop of coolant
- Compare optical reading to water content chart
Ā _____________________________________________________________
- Readings are temperature sensitive, so calibrate before each use:
- Calibrate the refractometer by placing a drop of new Evans Waterless on the refractometer glass. Use the small screwdriver supplied with the instrument to turn the calibration screw until the boundary between the upper blue field and the lower white field meet at 57.0.
- Always clean the glass and the daylight plate with a clean, soft cloth after each use and before each reading. Do not place under running water or submerge instrument while cleaning. Store unit in its original case in a cool, dry, area.
- Place a small amount of coolant, obtained from a location in the cooling system where the coolant is well-mixed, on the glass and close the daylight plate.
- Ideal is 3% or 55.7 BRIX; acceptable is 5% or 54.8 BRIX; below 54.4 BRIX, call 888/990-2665 (M-F 9 to 4:30 EST) for technical assistance. Vehicle may be driven with water content 7% or higher - technical intervention is strongly suggested to bring water content into recommended range for optimal performance.Ā
|
Ā ā°Brix
|
% WATER
|
|
57.0
|
0.0
|
|
56.5
|
1.0
|
|
56.1
|
2.0
|
|
55.7
|
3.0
|
|
55.2
|
4.0
|
|
54.8
|
5.0
|
|
54.3
|
6.0
|
|
53.9
|
7.0
|
Original: $50.27
-65%$50.27
$17.59Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Pre-calibrated for accuracy.
This Evans Cooling Refractometer isĀ designed to accurately test for residual water content. By determining the water content you'll be able to safely set up your cooling system with Evans Cooling products.
- Fast, simple optical method
- Requires only 1 drop of coolant
- Compare optical reading to water content chart
Ā _____________________________________________________________
- Readings are temperature sensitive, so calibrate before each use:
- Calibrate the refractometer by placing a drop of new Evans Waterless on the refractometer glass. Use the small screwdriver supplied with the instrument to turn the calibration screw until the boundary between the upper blue field and the lower white field meet at 57.0.
- Always clean the glass and the daylight plate with a clean, soft cloth after each use and before each reading. Do not place under running water or submerge instrument while cleaning. Store unit in its original case in a cool, dry, area.
- Place a small amount of coolant, obtained from a location in the cooling system where the coolant is well-mixed, on the glass and close the daylight plate.
- Ideal is 3% or 55.7 BRIX; acceptable is 5% or 54.8 BRIX; below 54.4 BRIX, call 888/990-2665 (M-F 9 to 4:30 EST) for technical assistance. Vehicle may be driven with water content 7% or higher - technical intervention is strongly suggested to bring water content into recommended range for optimal performance.Ā
|
Ā ā°Brix
|
% WATER
|
|
57.0
|
0.0
|
|
56.5
|
1.0
|
|
56.1
|
2.0
|
|
55.7
|
3.0
|
|
55.2
|
4.0
|
|
54.8
|
5.0
|
|
54.3
|
6.0
|
|
53.9
|
7.0
|